Digital Monitoring Products XR100 Series Programming Guide
68
Appendix
21.13 Area Account Number Messages
XR100 systems send an area account number instead of the system account number with the following
panelmessages/eventsbasedontheareaassignedtothezonethatinitiatedthealarm:
•WARNING:AlarmBellSilenced(S34)
•AbortSignalReceived(S45)
•CancelSignalReceived(S49)
•ALERT:SystemRecentlyArmed(S78)
•ALERT:ExitError(S80)
•ALARM:VerifySignalReceived(S96)(notcurrentlysentonareaarmingsystems)
The XR100 has always sent the area account number for the following messages:
•Zoneeventmessagesforallnon-24hourzonesassignedtoanarea
•Arming
•Disarming
The XR100 sends the following messages using the area account number based on the lowest area number
in Display Areas programming from the keypad being used:
•UserCodeAdd/Change/Delete
•DoorAccess/Denied
•User1AmbushandEarlyMorningAmbush
•SystemTestBegin/End
•UnauthorizedEntry
•Service Code and Service Request
The XR100 sends the following messages using the area account number based on the area number:
•LatetoArmforareaschedules