Programming guideXr500 SerieS Control Panel

Página 2 - MODEL XR500 SERIES

Digital Monitoring Products XR500 Series Programming Guideviii

Página 3 - Table Of COnTenTs

XR500 Series Programming Guide Digital Monitoring Products1IntroductIonIntroduction1.1 Before you BeginThis guide provides programming information f

Página 4 - Table of ConTenTs

Digital Monitoring Products XR500 Series Programming Guide2IntroductIon1.3 Encrypted Communications (XR500N/XR500E only)Some installations require s

Página 5

XR500 Series Programming Guide Digital Monitoring Products3IntroductIon1.8 KeypadsDMP offers multiple keypads in a variety of styles. All DMP keypads

Página 6

Digital Monitoring Products XR500 Series Programming Guide4IntroductIon1.10 Entering Alpha CharactersSome options during programming require you to

Página 7

XR500 Series Programming Guide Digital Monitoring Products5IntroductIon1.13 Multiple DisplaysFor many programming and user options, such as Area sel

Página 8

Digital Monitoring Products XR500 Series Programming Guide6InItIalIzatIonInitializationNOTE: WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE

Página 9

XR500 Series Programming Guide Digital Monitoring Products7CommuniCationCommunication3.1 COMMUNICATION CommunicationCongure the communication option

Página 10

Digital Monitoring Products XR500 Series Programming Guide8CommuniCation3.7 TEST RPT: YES Test ReportTest Report determines if test reports are sent

Página 11 - Introduction

XR500 Series Programming Guide Digital Monitoring Products9CommuniCationEnter R as the rst character for rotary (pulse) phone function. The R charac

Página 12

MODEL XR500 SERIESCONTROL PANEL PROGRAMMING GUIDEContains programming Instructions for use with the Model XR500, XR500N, XR500E Series Control PanelsX

Página 13 - FRI 12:51 PM

Digital Monitoring Products XR500 Series Programming Guide10CommuniCation3.23 SUB CODE NO Substitution CodeThis option displays when the Communic

Página 14 - NOBELL TST

XR500 Series Programming Guide Digital Monitoring Products11CommuniCation3.30 SPV/TRBL YES Supervisory/Trouble ReportsThis option displays when t

Página 15 - 1.13 Multiple Displays

Digital Monitoring Products XR500 Series Programming Guide12Network optioNsNetwork Options (XR500N/XR500E only)Network Options are provided to dene

Página 16 - Initialization

XR500 Series Programming Guide Digital Monitoring Products13Messaging setupMessaging Setup5.1 MESSAGING SETUP Messaging SetupThis section allows you

Página 17 - Communication

Digital Monitoring Products XR500 Series Programming Guide14Messaging setup5.10 EMAIL COMM TYPE Email Communication TypeNET CELL Choosing NET sends

Página 18 - 000.000.000.000

XR500 Series Programming Guide Digital Monitoring Products15Device SetupDevice Setup6.1 DEVICE SETUP Device SetupThis section allows you to dene the

Página 19

Digital Monitoring Products XR500 Series Programming Guide16Device SetupWhen all areas accessed by a door are armed, the door is locked by the panel.

Página 20

XR500 Series Programming Guide Digital Monitoring Products17Device SetupNote: The previous user actions also require the matching area(s) be programm

Página 21

Digital Monitoring Products XR500 Series Programming Guide18Device Setup6.14 OVERRIDE NO YES Schedule OverrideUse this option to allow door ON/OFF

Página 22 - (XR500N/XR500E only)

XR500 Series Programming Guide Digital Monitoring Products19Device Setup6.18.4 ACTIVATE ZONE 3REX? NO YES Activate Zone 3 Request to ExitSelecting

Página 23 - Messaging Setup

XR500 Series Programming Guide Digital Monitoring ProductsiTable Of COnTenTsIntroduction ...

Página 24

Digital Monitoring Products XR500 Series Programming Guide20Device Setup 734 Site Code Programming6.18.9 Site Code PositionEnter the site code s

Página 25 - Device Setup

XR500 Series Programming Guide Digital Monitoring Products21Device Setup6.18.15 No Communication with PanelThis option denes the relay action when

Página 26

Digital Monitoring Products XR500 Series Programming Guide22remote optionsREMOTE DISARM? NO YESRINGS: 8ARMED ANSWERRINGS: 8DISARMED ANSWERPC MOD

Página 27

XR500 Series Programming Guide Digital Monitoring Products23Remote options7.9 Manufacturer AuthorizationSelect YES to allow DMP Technical S

Página 28

Digital Monitoring Products XR500 Series Programming Guide24remote options7.13.4 Entré Backup IP Address This option displays only if NET is cho

Página 29

XR500 Series Programming Guide Digital Monitoring Products25SyStem RepoRtSSystem Reports8.1 SYSTEM REPORTS System ReportsSelect specic system report

Página 30

Digital Monitoring Products XR500 Series Programming Guide26SyStem OptiOnSSystem Options9.1 SYSTEM OPTIONS System OptionsThis section allows you to s

Página 31

XR500 Series Programming Guide Digital Monitoring Products27SyStem OptiOnS9.6 CRS ZONE TM: 4 Cross Zone TimeEnter the time allowed between zone fau

Página 32 - Remote Options

Digital Monitoring Products XR500 Series Programming Guide28SyStem OptiOnSGMTCity/Time Zone GMT City/Time Zone0London, Monrovia, Lisbon, Dublin, Casa

Página 33

XR500 Series Programming Guide Digital Monitoring Products29SyStem OptiOnSFor example, when Spanish is selected at a keypad, the User Menu and Status

Página 34

Digital Monitoring Products XR500 Series Programming GuideiiTable of ConTenTs3.31 Opening/Closing and User Reports ...

Página 35 - System Reports

Digital Monitoring Products XR500 Series Programming Guide30SyStem OptiOnS9.19 WLS AUDIBLE: DAY WIRELESS AUDIBLEANY DAY MIN Wireless Audible A

Página 36 - System Options

XR500 Series Programming Guide Digital Monitoring Products31SyStem OptiOnS9.26 ALLOW OWN USER CODE CHG? NO YES Allow Own User Code ChangeThis optio

Página 37

Digital Monitoring Products XR500 Series Programming Guide32bell OptiOnsBell Options10.1 BELL OPTIONS Bell OptionsThis section allows you to prog

Página 38

XR500 Series Programming Guide Digital Monitoring Products33Output OptiOnsOutput Options11.1 OUTPUT OPTIONS Output OptionsThis section allows you to

Página 39

Digital Monitoring Products XR500 Series Programming Guide34Output OptiOns11.8 ENTRY OUT: 0 Entry OutputEnter the output number to turn on

Página 40

XR500 Series Programming Guide Digital Monitoring Products35Output INFORMAtIONOutput Information12.1 OUTPUT INFO Output InformationThis section a

Página 41 - ZIP CODE: 0

Digital Monitoring Products XR500 Series Programming Guide36Output GrOupsOutput Groups13.1 OUTPUT GROUPS Output GroupsThis function allows you to ass

Página 42 - Bell Options

XR500 Series Programming Guide Digital Monitoring Products37Menu DisplayMenu Display14.1 MENU DISPLAY Menu DisplayMenu Display allows you to select a

Página 43 - Output Options

Digital Monitoring Products XR500 Series Programming Guide38StatuS LiStStatus List15.1 STATUS LIST Status ListThis function allows you to select the

Página 44

XR500 Series Programming Guide Digital Monitoring Products39StatuS LiSt15.5 BURGLARY ZONES: Burglary ZonesSpecies the keypad addresses (1 through 16

Página 45 - Output Information

XR500 Series Programming Guide Digital Monitoring ProductsiiiTable Of COnTenTs6.18.7 Card Options ...

Página 46 - Output Groups

Digital Monitoring Products XR500 Series Programming Guide40Printer rePortsPrinter Reports16.1 PRINTER REPORTS Printer ReportsThis section allows you

Página 47 - Menu Display

XR500 Series Programming Guide Digital Monitoring Products41PC Log RePoRtsPC Log Reports17.1 PC LOG REPORTS PC Log ReportsThis section allows you to

Página 48 - Status List

Digital Monitoring Products XR500 Series Programming Guide42PC Log RePoRts17.11 SUPV MSG NO YES Supervisory ReportsSends system monitor reports, suc

Página 49

XR500 Series Programming Guide Digital Monitoring Products43AreA InformAtIon Area Information18.1 AREA INFORMATION Area InformationAllows you to assi

Página 50 - Printer Reports

Digital Monitoring Products XR500 Series Programming Guide44AreA InformAtIon18.5 CLS CHK NO YES Closing CheckSelect YES to enable the panel to verify

Página 51 - PC Log Reports

XR500 Series Programming Guide Digital Monitoring Products45AreA InformAtIon 18.11 * UNUSED * Area NameThe area name can be up to 32 alphanumeric cha

Página 52 - Supervisory Reports

Digital Monitoring Products XR500 Series Programming Guide46AreA InformAtIon18.17 LATE OUTPUT: 0 Late Output NumberEnter the output to turn on when

Página 53 - Area Information

XR500 Series Programming Guide Digital Monitoring Products47Zone InformatIon Zone Information19.1 ZONE INFORMATION Zone InformationZone Information a

Página 54

Digital Monitoring Products XR500 Series Programming Guide48Zone InformatIon19.4 ZONE TYPE: BLANK Zone TypeThe Zone Type denes the panel respons

Página 55

XR500 Series Programming Guide Digital Monitoring Products49Zone InformatIon to individual areas and use remote LEDs at the keyswitch. The LED turns

Página 56

Digital Monitoring Products XR500 Series Programming GuideivTable of ConTenTs9.8 Power Fail Delay ...

Página 57 - Zone Information

Digital Monitoring Products XR500 Series Programming Guide50Zone InformatIonDMP Wireless For a DMP 1100X Wireless Receiver set the House Code from 1

Página 58

XR500 Series Programming Guide Digital Monitoring Products51Zone InformatIon SELECT MINUTES: 0 3 60 240 Press the Select key under the

Página 59

Digital Monitoring Products XR500 Series Programming Guide52Zone InformatIon19.11.2 TRANSMITTERSERIAL#: XXXXXXXX Key Fob Serial NumberEnter the eig

Página 60

XR500 Series Programming Guide Digital Monitoring Products53Zone InformatIon 19.11.8 BUTTON PRESS TIME: XXXXX Button Press TimeThis option spec

Página 61

Digital Monitoring Products XR500 Series Programming Guide54Zone InformatIon19.11.11 OUTPUT ACTION:yyy: XXXXXXXX Output ActionThis option allows y

Página 62

XR500 Series Programming Guide Digital Monitoring Products55Zone InformatIon 19.12.4 NRM OPEN NO YES Normally OpenSelect NO if the contact connecte

Página 63 - Output Number

Digital Monitoring Products XR500 Series Programming Guide56Zone InformatIon19.16 OUTPUT NO: 0 Output NumberYou can specify any of the Relay Outp

Página 64 - End-of-Line

XR500 Series Programming Guide Digital Monitoring Products57Zone InformatIon 19.21 RETARD NO YES Zone Retard DelayWhen you select YES, the zone ope

Página 65 - Normally Open

Digital Monitoring Products XR500 Series Programming Guide58Zone InformatIon19.30 Report with Account Number for AreaThis option is only available

Página 66

XR500 Series Programming Guide Digital Monitoring Products59StoPStop20.1 STOP StopSave ProgrammingWHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROU

Página 67

XR500 Series Programming Guide Digital Monitoring ProductsvTable Of COnTenTs12.6 Supervision Time ...

Página 68 - Set Lockout code

Digital Monitoring Products XR500 Series Programming Guide60Feature upgradeFeature Upgrade22.1 FEATURE UPGRADE Feature UpgradeIn the Programming Menu

Página 69 - Set Lockout Code

XR500 Series Programming Guide Digital Monitoring Products61AppendixAppendix23.1 False Alarm ReductionSystem Recently Armed reportThe System Recentl

Página 70 - Feature Upgrade

Digital Monitoring Products XR500 Series Programming Guide62AppendixSerial NumberThis number is the network communicator serial number. Reference thi

Página 71 - Appendix

XR500 Series Programming Guide Digital Monitoring Products63AppendixExiting the Diagnostics programPress the COMMAND key until STOP displays. Press a

Página 72 - ▐’s represent the

Digital Monitoring Products XR500 Series Programming Guide64Appendix Walk Test To conduct the Walk Test, reset the control panel by momentarily pla

Página 73 - 23.4 Using the Walk Test

XR500 Series Programming Guide Digital Monitoring Products65Appendix CKIN:XXX/ZZZ END Trip Counter For DMP Wireless Check-in Test (WLS)Displays t

Página 74

Digital Monitoring Products XR500 Series Programming Guide66Appendix23.7 Events ManagerThe Events Manager allows you to delay sending certain report

Página 75

XR500 Series Programming Guide Digital Monitoring Products67Appendix23.10 FA Series Transmitter InformationA House ID Number is like an address for

Página 76 - 23.9 UserProlesRecord

Digital Monitoring Products XR500 Series Programming Guide68Appendix23.11 Keypad Bus and LX-Bus Zone Type DescriptionsThis section describes applica

Página 77

XR500 Series Programming Guide Digital Monitoring Products69Appendix23.12.1 Keypad Bus Zone Type DefaultsThese are complete spellings of the abbrevia

Página 78

Digital Monitoring Products XR500 Series Programming GuideviTable of ConTenTs18.12 Account Number ...

Página 79 - Keypad Bus Zone Type Defaults

Digital Monitoring Products XR500 Series Programming Guide70Appendix23.12.2 LX-Bus Zone Type DefaultsThese are complete spellings of the abbreviatio

Página 80 - LX-Bus Zone Type Defaults

XR500 Series Programming Guide Digital Monitoring Products71Appendix23.13 Common Keypad MessagesThere are several common keypad messages that the ke

Página 81 - 23.13 Common Keypad Messages

Digital Monitoring Products XR500 Series Programming Guide72Appendix23.14 Area Account Number MessagesXR500 systems send an area account number inst

Página 82

XR500 Series Programming Guide Digital Monitoring Products73RevisionsRevisions to This DocumentThis section explains the changes made to this documen