Installation
XRSuper6/XR20/XR40 Installation Guide
13
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
13.4 Ground start
To configure the panel for ground start operation, you must install the appropriate ground start module and
program one of the panel's available annunciator outputs for Ground Start operation. Refer to the panel
Programming Guide for complete programming information. This option must not be selected on a UL listed
system.
Reset Jumpers J16
14.1 Description
There are two reset jumpers located at the top right of the panel's circuit board labeled RESET. Momentarily
shorting these jumpers allows you to reset the microprocessor. Resetting the panel allows you to enter the
panel's internal programmer.
To reset the panel when first installing the system, place the blade of a slotted screwdriver across the two reset
jumpers after applying power to the panel.
To reset the panel while the system is operational (for example, prior to reprogramming), you can short the
jumpers without powering down the system.
After resetting the panel for programming, you must begin within 30 minutes. If you wait longer than 30
minutes, you will have to reset the panel again.
UNIVERSAL UL BURGLARY SPECIFICATIONS
15.1 Introduction
The programming and installation specifications contained in this section must be completed when installing the
XRSuper6/XR20/XR40 in accordance with any of the UL burglary standards. Additional specifications may be
required by a particular standard.
15.2 Wiring
All wiring must be in accordance with NEC, ANSI/NFPA 70, UL 681, and UL 611 for all burglary installations.
15.3 Police station phone numbers
The digital dialer telephone number programmed for communication must not be a police station phone number,
unless that phone number is specifically provided for that purpose.
15.4 Bypass reports
The bypass reports option must be programmed as YES for all UL burglary applications. See the XRSuper6/XR20/
XR40 Programming Guide (LT-0305).
15.5 System maintenance
Proper installation and regular maintenance by the installing alarm company and frequent testing by the end user
is essential to ensure continuous satisfactory operation of any alarm system. Offering a maintenance program
and acquainting the user with the correct procedure for use and testing of the system is also the responsibility
of the installing alarm company.
15.6 Cross zoning
Zones used for cross zoning must be installed to allow detection of the same event. Cross zoning shall not
conflict with UL 681 or 1641.
15.7 Ground Start
Ground Start phone lines must not be used for UL listed systems.
15.8 UL Listed Receivers
UL has verified operation with the DMP SCS-1 Security Receiver, Sur-Gard SG-HLR2-DG, FBII CP220PB, Osborne-
Hoffman Quick-Alert and Radionics D6500 receivers.