Digital Monitoring Products XR150/XR350/XR550 Series Installation Guide
20
InstallatIon
Cellular Modules
19.1 J24 Header
The J24 header is located to the right of the J7 Expansion Module on the right side of the circuit board and is used
to connect the DMP Model 263C CDMA or 263H HSPA+ Cellular Communicators. This provides a fully supervised alarm
communication path for the XR150/XR350/XR550 panel. Refer to the 263C (LT-1264), or 263H (LT-1270) Installation
Sheet for complete information.
19.2 Module Installation
1. Insert the PCB standoff end with anges into the standoff hole in the panel PCB.
2. Align the PCB standoff with the standoff hole in the module PCB.
3. Press the module PCB card 12 pin connector onto the Cell Module (J24) connector on the panel while applying
even pressure to both sides of the board to fully seat the module. See Figure 13.
Note: If needed, the PCB can be removed from the enclosure to allow placement of the cell module.
19.3 Connecting the Antenna
1. Attach a 381 cable to the SMA connector on the cell
module.
2. Position one of the supplied washers onto the other end
of the 381 SMA connector and push the threaded end
through an enclosure knockout.
3. Position the second washer onto the threaded end
extending through the knockout and secure the nut.
4. Attach the included 383 Antenna to the SMA connector.
See Figure 13.
Note: As an alternative, an antenna coax can be connected
directly to the cell module SMA connector when the
coax enters the enclosure via conduit.
Figure 13: Cellular Module Installation
XR150/XR350/XR550
Panel
SMA
Connector
PCB
Standoff
Celular Module
Nut
Washers
SMA
Connector
Antenna
Connector
Coax Cable from
Cellular Module
Model 381-2
Coax Cable from
the 263 module
Comentários a estes Manuais