Panel Specifications
1.1 Power supply
Transformer Input: 16.5 VAC or 40VA (Models 320 or 321) or 100VA (Model 322).
Standby Battery: 12 VDC 6.5Ah (40VA charges two batteries, 100VA charges three or four batteries))
Auxiliary Output: 12 VDC at 600mA with 40VA transformer
Bell Output: 12 VDC at 1 Amp
Inherent Power Limited
1.2 Communication
Built in Dialer communication to DMP Model SCS-1 Receivers
Built in Multiplex communication to DMP Model SCS-1 Receivers
Built in DDMX communication to DMP Model SCS-1 Receivers
Built in CID communication to non-DMP receivers
Optional Model 893 Dual Phone Line Module with phone line supervision
Can operate as a local system
1.3 Panel loops
Four 1K EOL burglary loops (loops 1 to 4)
One 3.3K EOL Class B powered loop with reset (loop 5)
1.4 Keypads and expanders
You can connect up to eight of the following keypads or expanders to the 1912XR keypad data bus:
670, 770, or 771 Alphanumeric Keypads
711, 714, and 715 Loop Expanders
5845LX Glassbreak single point detector
6155LX PIR single point detector
You can connect the following devices to the LX-Bus of the Model 862N, 862P, 872, and 881 Interface
Cards up to the maximum number of addresses. Also see Accessory Devices in section 4.1.
714 and 715 Loop Expanders - up to 25 devices
716 Output Expander - up to 25 devices
5845LX Glassbreak single point detector - up to 100 devices
6155LX PIR single point detector - up to 100 devices
The 714 and 715 Loop Expanders each provide four loops.
The 716 Output Expander provides four Form C relays (SPDT) and four 50mA switched grounds (open
collector) suitable for a variety of annunciation and control applications.
1.5 Output contacts
Two on-board auxiliary Form C outputs. See section 13.1. You can have up to 100 additional outputs when
using 716 Output Expanders and an 862N, 862P, 872, or 881 Interface Card.
Outputs require two Model 305 relays, each rated for 1 Amp at 30 VDC or 0.5 Amp at 120 VAC
The panel also provides four auxiliary voltage outputs rated for 50mA at 12 VDC. See section 14.1.
1.6 Enclosure specifications
The 1912XR is shipped installed in its enclosure with end of line resistors, battery leads, and programming
sheets.
Size: 12.5" x 11.5" x 3.0"
Weight: 6 lbs
Color: Black (61) or Grey (63)
Construction: 18 gauge cold rolled steel
Vista de página 0
1 2 3 4 5 6 ... 35 36

Resumo do Conteúdo

Página 1 - Panel Specifications

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 1Panel Specifications1.1 Power supplyTransformer Input: 16.5

Página 2 - Introduction

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 101912XR Installation GuideCannot exceed 6.5 with one 367 BatteryCannot exceed 13.0 wi

Página 3 - 2.5 Before you begin

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 117.7 Battery supervisionThe 1912XR tests the battery once ev

Página 4 - 2.7 How to use this guide

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 121912XR Installation GuidePowered Loop for 2-Wire Smoke Detectors11.1 Terminals 12 an

Página 5 - System Components

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 1312.2 Operational parametersEach burglary protection loop de

Página 6 - Accessory Devices

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 141912XR Installation Guide12 VDC Outputs 3 to 614.1 DescriptionFour 12 VDC, 50mA volt

Página 7 - 5.1 Mounting the enclosure

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 15Reset Jumper J1616.1 DescriptionThe reset jumper is located

Página 8 - 5.3 Connecting serial devices

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 161912XR Installation GuideUNIVERSAL UL BURGLARY SPECIFICATIONS17.1 IntroductionThe pr

Página 9 - Secondary Power Supply

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 17UL 1610 and 1076 SPECIFICATIONSCentral-Station and Propriet

Página 10 - 7.6 1912XR power requirements

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 181912XR Installation GuideUL 365 and 609 SPECIFICATIONSPolice Station Connected and L

Página 11 - Keypad Data Bus

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 19UNIVERSAL UL and NFPA FIRE ALARM SPECIFICATIONS22.1 Introdu

Página 12 - 12.1 Description

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 21912XR Installation GuideIntroduction2.1 DescriptionThe DMP 1912XR Command Processor

Página 13 - Dry Contact Relay Outputs

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 201912XR Installation GuideUL 985 NFPA 74 SPECIFICATIONSHousehold Fire Warning System

Página 14 - Telephone RJ Connector

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 21CommonNormally ClosedNormally OpenDevice Fail LEDOR1k ΩVolt

Página 15 - Reset Jumper J16

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 221912XR Installation Guide26.1 Indicating circuit module installationAC BELLAC1234 56

Página 16 - UL 1023 SPECIFICATIONS

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 2326.2 Multiple Indicating circuit modulesAC BELLAC1234 56 7

Página 17 - UL 1635 SPECIFICATIONS

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 241912XR Installation Guide26.3 Multiple Indicating circuit modules for zoned annuncia

Página 18 - UL 365 and 609 SPECIFICATIONS

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 2526.4 Dual Style D Loop module installationAC BELLAC1234 56

Página 19

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 261912XR Installation Guide26.5 Remote StationAC BELLAC1234 56 7 891011121314 151617 1

Página 20

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 2726.6 Supervised Remote Relay12345678Auxiliary PowerGroundAl

Página 21 - Device Fail LED

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 281912XR Installation Guide26.7 Cellular backup installation123456Panel Auxiliary Powe

Página 22 - 1912XR Installation Guide

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 29Troubleshooting Section27.1 DescriptionThis section of the

Página 23

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 32.3 Partitions and areasThe 1912XR can be programmed into fo

Página 24

1232841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282Problem Possible Cause SolutionLoops on an expansion carddata bus will not set.

Página 25 - EPROM Socket

LT-0169 (3/96)1232841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282MODEL 1912XRCOMMAND PROCESSORBURGLARY/FIRECONTROL PANEL/COMMU

Página 26 - 26.5 Remote Station

MODEL 1912XRCOMMAND PROCESSORINSTALLATION GUIDEFCC NOTICEThis equipment has been tested and found to comply with the limits for a Class A digital devi

Página 27 - 26.6 Supervised Remote Relay

TABLE OF CONTENTSPanel SpecificationsPower supply... 1.1Communica

Página 28 - DCX Systems

SectionSmoke and Glassbreak Detector OutputTerminal 11 ... 10.1Cu

Página 29 - Troubleshooting Section

SectionTABLE OF CONTENTSUL 1635 SpecificationsSystem trouble display ... 20.1Digit

Página 30

SectionCalifornia State Fire Marshal SpecificationsBell output definition ...

Página 31 - INSTALLATION GUIDE

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 41912XR Installation Guide2.6 About this guideThe information contained in this guide

Página 32

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 5System Components3.1 DescriptionThe DMP 1912XR system is mad

Página 33

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 61912XR Installation GuideAccessory Devices4.1 Loop and output modules and interface c

Página 34

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 7Installation5.1 Mounting the enclosureThe metal enclosure fo

Página 35

Digital Monitoring Products, Inc. 1912XR Installation GuidePage 81912XR Installation Guide5.2 Mounting keypads and loop expandersSecurity Command keyp

Página 36

1912XR Installation GuideDigital Monitoring Products, Inc. 1912XR Installation GuidePage 9Primary Power Supply6.1 AC terminals 1 and 2Connect the tran

Comentários a estes Manuais

Sem comentários