123
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
Problem Possible Cause Solution
Loops on an expansion card
data bus will not set.
Too much line noise.
Too long of a wire run to devices.
Too small a wire size or
insufficient auxiliary power.
Troubleshooting Section continued
Move wires away from RF sources.
Relocate panel closer to devices.
Replace with a larger wire size or
add an auxiliary power supply.
Loop expanders are incorrectly
addressed.
There are unused loops on one or
more expanders.
Correct the address settings to
match the panel's programming.
Leave as is or assign loops to an
area.
Too much current draw from
terminals 7, 11, the output relays,
and/or the data bus of an
expansion card.
LPX Setup shows overlapped,
misssing, or extra loops.
Reduce current draw to below the
600mA allowable.
Install a UL listed power supply
Thermal circuit breaker on
panel pops on and off.