
XR500 Series Programming Guide Digital Monitoring Products
21
Device Setup
6.18.15 No Communication with Panel
This option denes the relay action when communication with the panel has not occurred
for ve seconds. Press any top row Select key to display relay action options. Press the
Back Arrow key to return to the NO OF USER CODE DIGITS:.
Choose the action required:
Press the rst Select key to choose OFF [Default] (Relay Always Off) — The relay does not
turn on when any Wiegand string is received. Off does not affect any REX operation.
Press the second Select key to choose SITE (Accept Site Code) — Door access is granted
when the Wiegand site code string received matches any site code programmed at SITE
CODE ENTRY. For details refer back to the REQUIRE SITE CODE option.
Press the third Select key to choose ANY (Any Wiegand Read) — Door access is granted
when
any Wiegand string is received.
Press the fourth Select key to choose ON (Relay Always On) — The relay is always on.
Press the COMMAND key to display the next action.
Press the rst Select key to choose LAST (Keep Last State) — The relay remains in the
same state and does not change when communication is lost.
After choosing the action, the NO COMM WITH PNL option and the newly dened action
display.
Programming is now complete. Press the COMMAND key to display DEVICE NO.
NO COMM WITH PNL
OFF SITE ANY ON
NO COMM WITH PNL
OFF
NO COMM WITH PNL
LAST
NO COMM WITH PNL
SITE
NO COMM WITH PNL
ANY
NO COMM WITH PNL
ON
Comentários a estes Manuais