INTRODUCTION
Product Specications
1.1 Power Supply
Transformer Input: Model 327, plug-in — Primary input: 120 VAC, 60 Hz, Secondary output: 16.5 VAC 50 VA
Model 322, wire-in — Primary input: 120 VAC, 60 Hz, Secondary output: 16 VAC 56 VA
Standby Battery: 12 VDC, 1.0 Amps Max. charging current
Models 365, 366, 367, 368, or 369
Replace every 3 to 5 years
* Auxiliary: 12 VDC output at 1.5 Amp Max
* Bell Output: 12 VDC at 1.5 Amp Max
Note: The combined Auxiliary and Bell outputs total cannot exceed 3 Amps with a 50 VA or 56 VA Transformer.
All circuits are inherent Power Limited except the red battery wire and AC terminal.
* For UL installations, the total current combined from Auxiliary and Bell Power cannot exceed:
1.3 Amps with a 50 VA transformer, 1.0 Amp Max for Auxiliary Power
1.9 Amps with a 56 VA transformer, 1.0 Amp Max for Auxiliary Power and 1.5 Amp Max for Bell
1.2 Communication
Built-in network communication to DMP Model SCS-1/SCS-1R Receivers (XR100N only)
Built-in dialer communication to DMP Model SCS-1/SCS-1R Receivers
Built-in Contact ID communication to non-DMP receivers
Optional 893A Dual Phone Line Module with phone line supervision
Can operate as a local panel
1.3 Panel Zones
Eight 1k Ohm EOL burglary zones (zones 1 to 8)
Two 3.3k Ohm EOL powered zone with reset (zones 9 and 10)
1.4 Keypad Bus
You can connect up to eight of the following supervised keypads and expansion modules to the keypad bus:
• Alphanumeric keypads • Four- and/or single-zone expansion modules
• Single-zone detectors • Access control modules
1.5 LX-Bus™
You can connect the following devices to the LX-Bus™ provided on the panel. See Accessory Devices in section 3.4.
• Four- and/or single-zone expansion modules • Single-zone detectors
• Relay output expansion modules • Graphic annunciator modules
1.6 Outputs
The XR100 Series provide two Single Pole, Double Throw (SPDT) relay outputs which require the installation of two
Model 305 relays, each rated 1 Amp at 30 VDC resistive (power limited sources only). A Model 431 Output Harness is
required to use these outputs.
The XR100 Series panels also provide four open collector outputs rated for 50mA each. The open collector outputs
provide ground connection for a positive voltage source. A Model 300 Output Harness is required to use these
outputs.
1.7 Enclosure Specications
The XR100 Series panels are shipped in an enclosure with a transformer, End-of-Line resistors, battery leads, user’s
guide, and programming sheets.
Model 350A Enclosure
Enclosure size: 17.5” W x 13.5” H x 3.75” D
Color: Gray (G)
Construction: 18-gauge with 16-gauge door
Model 350 Enclosure
Enclosure size: 17.5” W x 13.5” H x 3.5” D
Color: Gray (G) or Red (R)
Construction: 18-gauge, cold-rolled steel