XRSuper6/XR20/XR40 Installation Guide Digital Monitoring Products
21
ComplIanCe
False Alarm Reduction Programmable Options (continued)
25.2 Call Waiting (ANSI/SIA CP-01-2000)
The Call Waiting default setting is disabled. To cancel the Call Waiting feature, program * (star) 7 0 P
(pause), the standard telephone code prex that cancels call waiting, into the telephone number string.
Cancel Call Waiting for telephone lines that have Call Waiting operational on the telephone line. See the
XRSuper6/XR20/XR40 Programming Guide (LT-0305).
Caution: A call waiting cancel programmed on a non-call waiting telephone line, would prevent
communication to the central station.
25.3 Occupied Premise (ANSI/SIA CP-01-2000)
When only two areas are used, and area one is named Perimeter, and area two is named Interior, and no exit
type zone transition occurs during the exit delay because the premise continues to be occupied, the Interior
area will automatically disarm at the end of the exit delay.
25.4 Entry Delay (ANSI/SIA CP-01-2000)
Only use Entry Delay 1. Do not use Entry Delay 2. See the XRSuper6/XR20/XR40 Programming Guide
(LT-0305).
25.5 Local Bell (ANSI/SIA CP-01-2000)
All non-re zones such as Night, Day, Exit, Aux1 and Aux 2 must be programmed for local bell enabled with
a bell cutoff time set to a minimum of 6 minutes to provide a cancel window of 5 minutes or greater. This
does not apply to manually operated zone types such as Panic and Emergency.
25.6 Minimum Installation Requirements (ANSI/SIA CP-01-2000)
SIA CP-01-2000 minimum system installation requirements include an XRSuper6, XR20, or XR40, a UL listed
local Bell, and off premise DACT communication to an SCS-1R receiver plus one of the following compatible
keypads.
690/690F, 790/790F Security Command™ keypads
693/793 Easy Entry™ keypads
7060, 7063, 7070, or 7073 Thinline™ keypads
7060A, 7063A, 7070A, or 7073A Aqualite™ keypads
7760 Clear Touch™ keypad