XRSuper6/XR20/XR40 Installation Guide Digital Monitoring Products
3
IntRoduCtIon
System Components
3.1 Description
The DMP system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC
transformer, and a 12 VDC 7.0 Ah battery. You can add Security Command keypads to the system and can
also connect auxiliary devices to the panel’s open collector outputs to expand the basic system. Combined
current requirements of additional modules may require an auxiliary power supply. Refer to the Standby
Battery Power Calculation section in this guide when calculating power requirements. In addition, up to 32
points of zone expansion can be added to the XR40, and 16 points to the XR20 and XRSuper6.
3.2 Wiring Diagram
The system wiring diagram in Figure 1, on the following page, shows some of the accessory devices you can
connect for use in various applications. A complete description of each module follows.
3.3 Lightning Protection
Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on input and
output circuits. A transorb is provided for the Smoke Detector Output Circuit (Terminal 11). This transient
protection provides additional resistance to electrical surges such as lighting. Additional surge protection is
available by installing the DMP 370 or 370RJ Lightning Suppressors.
3.4 Accessory Devices
Interface Adaptor and Interface Cards
733, 734 Wiegand Interface
Cards
Provides system codeless entry, and arming and disarming using access control readers.
Zone and Output Expansion Modules
710 Bus Splitter/Repeater Allows you to increase keypad wiring distance to 2500 feet.
711 Single Point Zone Expanders Provides one Class B zone for connecting burglary devices.
714, 714-8, 714-16 Zone
Expanders
Provides Class B zones for connecting burglary and non-powered re devices.
712-8 Zone Expander Provides Class B zones for connecting burglary devices.
715, 715-8, 715-16 Zone
Expanders
Provides 12 VDC Class B powered zones for connecting smoke detectors, glassbreak
detectors, and other 2- or 4-wire devices.
DMP Two-Way Wireless Devices
1100D/*1100DH/*1100DI Wireless
Receivers
Supports transmitters in residential or commercial wireless operation.
1101 Universal Transmitter Provides both internal and external contacts that may be used at the same time to yield two
individual reporting zones from one wireless transmitter.
1102 Universal Transmitter Provides an external contact.
* 1114 Four-Zone Expander Provides four wireless zones
* 1116 Relay Output Provides one Form C relay
* 1117 LED Annunciator Provides a visual system status indicator
* 1121 PIR Motion Detector Provides motion detection with pet immunity.
1125 PIR Motion Detector Provides multiple lens congurations, dual coverage area selection, and sensitivity
adjustments.
* 1129 Glassbreak Detector Detects the shattering of framed glass mounted in an outside wall and provides full-pattern
coverage and false-alarm immunity.
* 1139 Bill Trap Provides a silent alarm option for retail and banking cash drawers.
1142BC Two-button Panic Belt
Clip Transmitter
Provides portable two-button panic operation.
1142 Two-button Panic
Transmitter
Provides permanently mounted under-the-counter two-button panic operation.
* 1145 (Four-Button)
* 1146 (Two-Button)
* 1147 (One-Button)
Key Fob transmitters designed to clip onto a key ring or lanyard.
*These devices have not been investigated by a Nationally Recognized Testing Laboratory (NRTL).