ZONE INFORMATION
14.12.1 Message To Transmit
You can send two report types to the receiver: Alarm and Trouble. These are represented
by the characters A and T. Press any Select key to display the zone report options.
ALARM - Selecting A allows an alarm report to be sent to the receiver and the bell output
to activate according to zone type. See the Bell Action section. The zone name appears
in the panel’s alarmed zones status lists.
TROUBLE - Selecting T allows a trouble report to be sent to the receiver and the zone
name to appear in the panel’s alarmed zones status lists.
LOCAL - When you select L, an alarm report is NOT sent to the receiver. The bell output
still activates according to zone type and the zone name appears in the panel’s alarmed
zones status lists.
– (dash) - When you select – , reports are NOT sent to the receiver. The bell output does
not activate and there is no display in the panel’s alarmed zones status list. Only the
programmed Output Number activates.
14.12.2 Output Number
You can specify any of the outputs/Favorites on the XT30/XT50 to be activated by a zone
condition. The output/Favorite can be activated regardless of the report to transmit or
whether or not the zone is programmed as local. An output activated by a non-24-hour
armed zone is turned off when the zone’s area is disarmed by a user.
To enter an Output Number, press any Select key followed by the output number 1 to 4,
31-34, 41-44, or F1-F20. Press the COMMAND key.
14.12.3 Output Action
Entering an Output Number displays this option that allows you to assign an output
action to the relay. A description of the available output actions is given below:
STEADY - The output is turned on and remains on until the area is disarmed, an output
cutoff time expires, or the output is reset from the keypad User Menu.
PULSE - The output alternates one second on and one second off until the area is
disarmed, an output cutoff time expires, or the output is reset from the keypad User
Menu.
MOMENTARY - The output is turned on only once for one second.
FOLLOW - The output is turned on and remains on while the zone is in an off normal, or
bad condition. When the zone restores, the output is turned off.
After you have selected the Message To Transmit, the display prompts you for the same
three selections for Disarmed Short, Armed Open, and Armed Short conditions. If the
zone is a 24-hour type, only the Armed Open and Armed Short conditions are displayed.
When you have programmed all of the zone conditions, the Swinger Bypass selection is
then dis played.
14.13 Swinger Bypass
Selecting YES allows the zone to be swinger bypassed by the panel according to the
programming in Swinger Bypass Trips and Reset Swinger Bypass. The Bypassed zone
displays in the keypad Status List. Selecting NO disables swinger bypassing for this zone.
How it works
If within one hour, a zone trips the total number of times as specied in Swinger Bypass
Trips, the panel bypasses it until the following conditions occur; the area in which
the zone is assigned is disarmed, the zone is manually reset through the Bypass Zones
keypad User Menu function, the zone remains normal for one hour and the Reset Swinger
Bypass is YES.
If the zone trips fewer than the specied times within one hour of the rst trip, the
bypass trip counter returns to 0 (zero) and the process must be repeated.
A report of the swinger bypass is sent to the receiver if Bypass Reports is YES.
MSG: TROUBLE
A T L -
OUTPUT NO: 0
ACTION:
STD PLS MOM FOLW
SWGR BYP NO YES