Digital Monitoring Products XT Series Programming Guide
42
APPENDIX
Walk Test
To conduct the Walk Test, reset the control panel by momentarily placing a jumper on
J16 then wait one minute. From the keypad, enter the code 8144. The keypad displays
WALK TEST. If the system is monitored and the communication type is DD or NET, the
system sends a System Test Begin report to the central station. All programmed zones
are included in the test.STD (Standard Walk Test) - Select STD to Walk test zones. All
programmed zones are included in the test.
WLS (Wireless Check-in Test) - Select WLS to automatically test 1100 Series wireless
transmitter communications. Includes all wireless devices except key fobs and
transmitters programmed for a supervision time of 0 (zero).
Note: For the XT30, Wireless Check-in Test operation only displays when connected to
1100D Wireless Receiver Version 105 or higher.
PIR (Wireless PIR Walk Test) - The PIR Walk Test allows the installer to verify the 1126
operation. When enabled, the 1126 or 1127 LED ashes each time motion is detected
for up to 30 minutes. This is a local test only and no messages are sent to the Central
Station.
Trip Counter for Walk Test (STD)
Displays the number of zone trips during the Walk Test.
Each time a selected zone trips, the keypad buzzes and the bell rings for two
seconds.
Each time a FI, FV, or SV zone trips, a Sensor Reset occurs.
END - Press the Select key directly below END to stop the Walk Test. When the Walk Test
ends or a 20 minute time-out expires, a nal Sensor Reset occurs. The System Test End
message is sent to the receiver along with Verify and Fail messages for each zone under
test. Faulted zones then display on the keypad.
Trip Counter For DMP Wireless Check-in Test (WLS)
Displays the number of wireless zones that automatically communicate a supervisory
check-in message.
• The number of zones that check in. (XX in the example).
• The total number of wireless zones programmed for supervision that should check
in. (ZZ in the example).
END - Select END to stop the Wireless Check-in Test. When the test ends or a 20-minute
time-out expires, normal wireless zone processing returns. If all transmitters check-in,
both numbers will match within three (3) minutes. If a transmitter has multiple zones
(1101, 1114, etc.), all zones will be included in the counts. Failed wireless zones will
then display on the keypad.
Test End Warning
When no zones have been tripped and ve minutes remain on the 20 minute Walk Test
timer, the keypad displays TEST END WARNING and the keypad tones. If no additional
test zone trips occur, the test ends and a nal Sensor Reset automatically occurs. The
System Test End message is sent to the receiver along with Verify and Fail messages for
each zone under WALK test. Faulted zones then display on the keypad.
Failed Zones Display
Each zone that did not trip at least once during the Walk Test displays on the keypad
that initiated the test. Any Fire (FI) Panic (PN) or Supervisory (SV) 24-hour zone that is
faulted at the end of the Walk Test displays a trouble condition for that zone regardless
of the message programmed for the open or short condition of the zone and a zone
trouble is sent to the receiver. Press the COMMAND key to display the next failed zone
.
For the Wireless Check-in Test, failed wireless zones display only on the keypad. Zone
Verify/Fail reports are not sent to the central station receiver for the wireless checkin
test.
WALK TEST
STD WLS PIR
WALK TEST
TRIPS: XXX END
WIRELESS TEST
CHKIN: XX/ZZ END
TEST END WARNING
SOUTH LOBBY
ZONE: 10 -FAIL
Vista de página 48