XTL/XTLC Programming Guide Digital Monitoring Products
19
OUTPUT OPTIONS
Output Options
10.1 Output Options
This section allows you to program output options for the 1116 and 1117 wireless
outputs.
Select from the following output numbers:
• 31 to 34
• 41 to 44
• F01 to F20 (To Activate Z-Wave Favorites)
10.2 Communication Failure Output
This output/Favorite turns on when the panel fails to communicate with the receiver
after eight successive attempts. Enter 0 (zero) to disable this output.
Note: To turn off the Communication Failure Output, disarm the panel or turn the
output off using the User Menu Outputs On/Off function.
10.3 Fire Alarm Output
This output/Favorite turns on any time a re type zone is placed in alarm. The output
turns off using the Sensor Reset option when no additional re type zones are in alarm.
Enter 0 (zero) to disable this output.
10.4 Panic Alarm Output
This output/Favorite turns on any time a Panic Zone (PN) is placed in alarm. The output
turns off using the Sensor Reset option once all Panic Zones are restored. Enter 0 (zero)
to disable this output.
If a wireless ouput is programmed, the panel sends the Panic Test Cadence or the Panic
Alarm Cadence to the output when a Panic Test is performed or a Panic Zone is placed in
alarm.
10.5 Entry Output
This output/Favorite turns on at the start of the entry delay time. The output turns off
when the area disarms or the entry delay time expires. Enter 0 (zero) to disable.
10.6 Begin Exit Output
This output/Favorite turns on any time an exit delay time starts. The output turns off
when the system arms or when the arming has been stopped. Enter 0 (zero) to disable.
10.7 End Exit Output
This output/Favorite turns on any time an exit delay time ends. The output turns off
when the system disarms. Enter 0 (zero) to disable.
10.8 Armed Output
This output/Favorite turns on any time an area of the system is armed. The output turns
off when the system completely disarms. Enter 0 (zero) to disable this output.
Favorites:
For a Home/Away system:
• When the system is armed AWAY, the programmed Favorite activates.
• When the system is armed SLEEP, the programmed Favorite plus 1 is activated.
For example, If the Armed Output is F05, F06 activates when Sleep is armed.
• When the system is armed HOME, the programmed Favorite plus 2 is activated.
For example, If the Armed Output is F05, F07 activates when Home is armed.
For an All/Perimeter system:
• When the system is armed ALL, the programmed Favorite activates.
• When the system is armed PERIMETER, the programmed Favorite plus 1 is
activated.
For example, If the Armed Output is F05, F06 activates when Perimeter is armed.
For an Area system:
• When any area of the system is armed, the programmed Favorite activates.
OUTPUT OPTIONS
COM FAIL OUT: 0
FIRE ALR OUT: 0
PANC ALM OUT: 0
ENTRY OUT: 0
BEGIN EXIT: 0
END EXIT: 0
ARMED OUT: 0