XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products
15
SySTem oPTionS
System Options
6.1
SYSTEM OPTIONS
System Options
This section allows you to select system wide parameters used in the operation of
the XRSuper6/XR20/XR40 system. A description of each System Option follows:
6.2
MODE: ALL/PERIM
AREA A/P H/A
Mode
This congures the panel as either a four Area system (XR20/XR40 only), an All/
Perimeter system (Perimeter/Interior), or a Home/Away system (Perimeter, Interior,
and Bedrooms). Zones must be assigned to Bedrooms for the area to be active.
When using wireless zones for an Area (XR20/XR40 only) or All/Perimeter system,
the keypad trouble buzzer resounds every four hours when wireless zone trouble or
wireless low battery is displayed.
Unvacated Premise
When arming AWAY or ALL from a keypad at a system programmed for All/Perimeter
or Home/Away, and no exit type zone is faulted during Exit Delay (the exit door is
not opened to leave after arming), the system arms as HOME or PERIM by disarming
the interior areas including bedrooms at the end of the delay.
6.3
CLS CODE NO YES
Closing Code
When YES is selected, a code number is required for system arming. If NO is
selected, a code number is not required for system arming. Default is NO.
6.4
CLS CHK NO YES
Closing Check (XR20/XR40 Only)
Select YES to enable the panel to verify that all areas have been armed after a
schedule expires. If the Closing Check nds any areas disarmed past the scheduled
time, all keypads emit a steady beep and display CLOSING TIME!. Default is NO.
All zones in that area are delayed along with the Exit zone. Entry Delay times can
be from 30 to 250 seconds. Repeat the above for each entry delay being used in the
system.
6.5
ENTRY DELAY 1: 30
ENTRY DELAY 2: 60
Entry Delay 1
Enter the entry delay time for all exit type zones programmed to use Entry Delay 1.
When an armed Exit type zone is faulted, the keypad prewarn tone begins sounding.
ENTER CODE:- and the name of the zone causing the Entry Delay displays on all
keypads.
When the rst digit of a code is entered, the prewarn tone stops at the keypad.
If, within ve seconds, a valid user code is not entered or an invalid user code is
entered, the prewarn tone begins sounding again. Fifteen seconds must elapse
before entering a digit silences the prewarn tone again.
Note: When the SIA CP-01 option in System Options is set to NO, the rst digit
entered at the keypad does not stop the prewarn tone.
The area must be disarmed before the entry delay expires or an Alarm Message is
sent to the receiver and an alarm sounds. All Burglary type zones in all areas are
delayed along with the Exit zone.
Entry delay times can be from 30 to 250 seconds. Repeat the above for Entry Delay
2 if it is being used. Default is 30 seconds for Entry Delay 1.
Note: Specic Exit Error operation is based on the Entry Delay used (1 or 2) with an
EX type zone. See Exit Delay.
Note: For UL Installations, the combined Transmit Delay (Abort Window) and
Entry Delay must not exceed one (1) minute.