XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products
33
zone informaTion
11.12.3
ACTION:
Output Action
Entering an Output Number displays this prompt that allows you to assign an output
action to the relay. A description of the available output actions is given below:
STD PLS MOM FOLW
STEADY - The output is turned on and remains on until the area is disarmed, an
output cutoff time expires, or the output is reset from the keypad User Menu.
PULSE - The output alternates one second on and one second off until the area is
disarmed, an output cutoff time expires, or the output is reset from the keypad
User Menu.
MOMENTARY - The output is turned on only once for one second.
FOLLOW - The output is turned on and remains on while the zone is in an off
normal, or bad condition. When the zone restores, the output is turned off.
After you have made the three selections in sections 9.9.1 through 9.9.3, the
display prompts you for the same three selections for Disarmed Short, Armed Open,
and Armed Short conditions. If the zone is a 24-hour type, only the Armed Open and
Armed Short conditions are displayed. When you have programmed all of the zone
conditions, the Swinger Bypass selection is then dis played.
11.13
SWGR BYP NO YES
Swinger Bypass
YES allows the zone to be bypassed by the panel after one alarm, trouble, or local
trip within one hour. Selecting NO disables swinger bypassing for this zone. Default
is YES.
How Swinger Bypass works
If within one hour, a zone trips two times, the panel bypasses it until one of the
following conditions occur; the area in which the zone is assigned is disarmed, the
zone is manually reset through the Bypass Zones? keypad User Menu function, or the
zone remains normal for one hour and the Reset Swinger Bypass is YES.
After the rst trip, if the zone does not trip one more time before the remaining
time expires, the bypass trip counter returns to 0 (zero) and the zone must trip a
full two times within the next hour to be automatically bypassed.
A report of a swinger bypass is sent to the receiver if Bypass Reports has been
enabled. See the Bypass Reports section.
Bypassed zones are automatically reset when the area they are assigned to is
disarmed. All bypassed 24-hour zones are reset when the system is disarmed.
11.14
PREWARN: 12345678
Prewarn Address (XR40 only)
At the start of the entry delay, all keypad addresses dis play ENTER CODE:-. If you
want the prewarn to sound at all eight addresses, leave the default as shown.
To delete an address, press the matching number on the keypad. To disable
prewarning at all keypads, press a top row key to clear the addresses shown. Press
the COM MAND key when the address selection is com plete.
Note: On XRSuper6, XR20, and XR40 systems, the prewarn tone stops at the keypad
when the rst digit of a user code is entered. If, within ve seconds, a valid user
code is not entered or an invalid user code is entered, the prewarn tone begins
sounding again. Fifteen seconds must elapse before entering a digit silences the
prewarn tone again.
Note: When the SIA CP-01 option in System Options is set to NO, the keypad
cadence remains on during entry delay when the rst key is pressed at a keypad.
11.15
ENTRY DELAY: 1
Entry Delay
Select the entry delay timer for this zone. Entry delay timers 1 and 2 are
programmed in Entry Delay in the System Options menu.