Digital Monitoring Products XR20 Guia de Instalação Página 37

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 36
XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products
29
zone informaTion
11.9.3
SUPRVSN TIME: XX
Supervision Time
Press any top row key to select the supervision time required for the wireless zone.
Press COMMAND to accept the default time. Default is 240 minutes.
0 3 60 240
Select the required number of minutes. The transmitter must check in at least
once during this time or a missing condition is indicated for that zone. 1100 Series
transmitters automatically checkin based on the supervision time selected for the
wireless zone, no additional programming is needed. If two zones share the same
transmitter, the last programmed supervision time is stored as the supervision time
for both zones. Zero (0) indicates an unsupervised transmitter.
Note: For UL listed installations, refer to the 1100D Receiver Installation Guide
(LT-0692) for transmitter supervision time requirements.
Note: When the panel is reset or a receiver is installed or powered down and
powered up, the supervision timer restarts for all wireless zones.
11.9.4
LED OPER NO YES
LED Operation
This only displays when programming a panic or pendant transmitter. Select YES to
turn a panic or pendant LED on during normal operation. Select NO to turn the LED
off during normal operation. The LED always operates on all transmitters when the
transmitter case is open and the tamper is faulted. Default is YES.
Note: For listed holdup installations, set LED Operation to NO.
11.9.5
NEXT ZN NO YES
Next Zone
Select YES to return to the ZONE NO: - prompt to program a new zone. Select NO
to display the Alarm Action option.
1100 Series Key Fobs
For an 1100 Series Key Fob set the House Code from 1 to 50. See House Code programming in System
Options. Only zones 31-34 or 41-44 can be programmed as 1100 Series Key Fob zones. Refer to the 1100
Series Key Fob Programming Sheet (LT-0706) supplied with the 1100D/1100DI/1100DH Wireless Receiver
and the 1100 Series Key Fob Install Guide (LT-0703) as needed.
To operate arming and disarming properly, the Key Fob should be assigned to a User Number with
appropriate area assignments, however, the User Number does not have to exist at the time the Key
Fob is programmed. The User Number can be added at the User Menu later by the User.
Note: Key Fobs have not been investigated by UL and are not intended for UL listed applications.
The following programming continues from when Key Fob YES is selected.
11.10.1
KF USER NO:
Key Fob User Number
Enter the User Number used to identify the key fob user and their arming and
disarming authority. Default is blank.
— User number 1 to 16 on XRSuper6 panels
— User number 1 to 32 on XR20 panels
— User number 1 to 64 on XR40 panels
NOT IN USE
Displays when the User Number entered does not exist in User Code programming.
The key fob can be added, but the user must eventually be added to cause the key
fob to operate.
11.10.2
SERIAL #: -
Key Fob Serial Number
Enter the eight-digit serial number found on the wireless device.
ALREADY USED Zxx
Displays when the serial number is already programmed. The programmed zone
number displays.
Vista de página 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 51 52

Comentários a estes Manuais

Sem comentários