Digital Monitoring Products XR150/XR350/XR550 Series Programming Guide
16
DEVICE SETUP
When an area(s) is chosen, the following displays are allowed:
Armed Status of the selected area(s)
Zone Alarms and troubles for burglary (NT, DY, EX, A1, A2) type zones assigned to the
selected area(s)
• Late to Close status of the selected area(s)
• Zone Status (normal/fault) of zones that are assigned to the selected area(s)
Options and Actions Not Affected
The following options are not affected by the Display Areas operation. The User Code
authority level controls access to these items.
• Sensor Reset Menu • Outputs On/Off Menu • System Status Menu
• System Test/Panic Test • User Proles • Forgive Anti-Passback
• Service Request • Set System Time and DatE
• Fire Drill • Display Events
• 24-hour zones display at keypads based on Status List programming only
Note: A common area and its operations cannot be assigned to a specic keypad.
Display Areas example: When Device 1 has Display Areas set to 20, 21, and 22, it
annunciates troubles and alarms only for zones assigned to those areas.
When arming/disarming from Device 1, only areas 20, 21, and 22 may be armed/disarmed,
even when the User Prole has authority to arm/disarm other system areas.
Exception: Disarming of other areas not selected in Display Areas can be accomplished
by presenting a card that has disarming authority and matching prole areas with areas
assigned in Device Access Areas.
6.10 Strike Time
Enter a door access time, between 1 and 250 seconds, during which a keypad or access
control device relay is activated. Magnetic locks or electric door strikes are connected to
the relay and released for the length of the strike time. Default is 5 seconds.
Enter 0 (zero) to activate the device relay with a toggle action. This allows the user to
activate or deactivate the device relay each time a valid user code is entered. The device
relay is activated or deactivated until a user code is entered again.
Note: The Request to Exit door access time of a keypad or Model 734/734N Wiegand
Interface Module is not affected by this selection. It remains at 5 seconds.
6.11 Strike Delay
Enter the number of minutes, 0 to 9, to delay a door strike after a valid code is entered or
a card read occurs. When a valid code or card read or code is received, the activation of
the door strike is delayed for the number of minutes programmed. The standard door strike
message is sent to the Central Station receiver and logged in the Display Events at the
time of card read or code entry and is not delayed. During this delay, all subsequent codes
entered or cards presented to the reader for a door strike are ignored and no record of the
attempt is stored. Enter 0 (zero) to disable. Default is 0 (zero).
6.12 Fire Exit Release
Select YES to allow the door access relay at this address to be released whenever Fire panic
keys are pressed or a Fire or Fire Verify zone alarm is in the Status List. The relay is reset
whenever a Sensor Reset is performed to remove all Fire and Fire Verify zone alarms from the
Status List. Select NO to not allow the door access relay at this address to be released.
6.13 Public Door
Select YES to allow the door access relay at this address to be released whenever the
Lockdown command is issued from the keypad User Menu or remote command. The relay is
reset whenever a Sensor Reset is performed.
Select NO to not allow the door access relay at this address to be released. Default is NO.
6.14 Output Group
Select YES to allow the output group (relays) assigned to the user prole to turn ON when
the device relay is activated for the programmed strike time. This could be used to operate
an elevator control. Default is NO. See the User Proles section in the Appendix of this
document for more information about proles.
6.15 Schedule Override
Use this option to allow door ON/OFF schedules to be overridden by the armed condition
of the system. Selecting YES causes the on time for a door schedule to be ignored when all
areas assigned to Access Areas for this device are armed. Should any area become disarmed
after the door schedule on time, the device output turns on. A door output which is on
during a disarmed period automatically turns off when all access areas assigned to the
device become armed, even if the scheduled off time has not been reached. This feature
can be used to keep doors locked when a factory opens late, or is forced to close early, due
to a snow storm or other cause. Select NO to allow door schedules to operate independent
of system armed status.
STRIKE TIME: 5
STRIKE DELAY: 0
FIRE EXIT NO YES
PUBLIC DR NO YES
OUT GROUP NO YES
OVERRIDE NO YES