22
REMOTE OPTIONS
7.12.5 Entré Backup TCP Port
This option displays only if NET is chosen for the Entré connection. Enter the backup
programming port number for the outbound Entré connection in case the connection to the
primary IP fails. Default is 2001.
7.12.6 Entré Checkin
Select the rate at which check-in messages are sent over the Entré connection. Select 0
(zero) to disable check in messages. Range is 0, 3-240 minutes. Default is 0.
7.12.7 Entré Passphrase
To enable encryption enter an 8 to 16-character Passphrase using alphanumeric characters.
If you leave the Passphrase blank, the panel communicates with Entré, but the data is not
encrypted. The Passphrase is blank by default.
7.13 Send Local Changes
This option allows the panel to automatically update Remote Link at the central station
with any changes made to the panel.
Select NET or DD to send local programming changes or User Menu changes to user codes,
user proles, schedules, or holiday dates to Remote Link after exiting the programming or
User Menu. If NET is selected, changes are sent using Network. If DD is selected, changes
are sent using Dialer. Default is NO to disable this feature.
7.13.1 Remote Change IP
This option displays when NET is selected for Send Local Changes. Enter the IP address
containing up to 12 digits. The Net IP Address must be unique and cannot be duplicated
on the network. Enter all 12 digits and leave out the periods. For example, enter IP
address 192.168.0.250 as 192168000250. The periods display automatically. Default is
000.000.000.000
7.13.2 Remote Change Port
This option displays when NET is selected for Send Local Changes. Enter the Port number.
Valid numbers are from 0 to 65535. Default is 2002.
7.13.3 Remote Telephone Number
This option displays when DD is selected for Send Local Changes. Press COMMAND to
enter the phone number the panel dials when sending programming changes. After entering
a phone number, the panel sends any panel changes to Remote Link.
The phone number can have two lines of 16 characters each to equal 32. Enter a P to
program a two second pause in the dialing sequence. The P character counts as part of the
32 allowable characters. Enter *70P as the string rst characters to cancel call waiting. Dial
tone detect is an automatic panel function.
7.14 App Key
Enter the 8-digit App Key obtained in your Dealer Settings tab at
vk.securecomwireless.com.
This option is a security feature of the Virtual Keypad iPhone/Android App used only
when your Dealer Settings at vk.securecomwireless.com have “EASYconnect” set as the
Communication Type.
This communication option is only available for panels with onboard network and is used to
eliminate the need for a static IP address programmed in Network Options. To enter a new
App Key, press any Select key and enter any combination of 8 digits. Press COMMAND. The
default for this option is blank.
ENTRE BACKUP TCP
PORT: 2001
ENTRE CHECKIN
MINUTES: 0
ENTRE PASSPHRASE
-
CHANGES? NO
NO NET DD
SEND LOCAL
SEND LOCAL
REMOTE CHANGE IP
000.000.000.000
REMOTE CHANGE
PORT: 2002
REMOTE PHONE NO.
-
-
APP KEY: