Digital Monitoring Products XR150/XR350/XR550 Series Programming Guide
34
OUTPUT GROUPS
Output Groups
13.1 Output Groups
This function allows you to assign outputs to groups. Output groups can be assigned to
other areas of programming such as Output Options or Alarm Action of Zone Information,
just like single outputs are assigned. This allows the entire group of outputs to turn on and
off as required by the programming option.
13.2 Group Number
Enter a group number from 1 to 20. Up to 20 different groups may be assigned.
13.3 Group Name
The group name displays. To change the default name, press any top row Select key then
enter up to 32 characters for the group name. Press COMMAND to enter the outputs to be
assigned to the group.
13.4 Output Number
Enter the Output number. Entry range is 1 to 6, 450 to 474, 480 to 499, 500 to 999
(outputs), F1 to F20 (Favorites), D1 to D16 (doors), and G1 to G20 (groups). The maximum
number of outputs that can be assigned to a specic group is eight.
An output group may be assigned as one of the output numbers in another output group.
Example: Output Group 1 consists of only four assigned outputs. Output Group 1 could be
assigned as one output in Output Group 2. Output Group 2 could still have 7 other outputs
assigned to that group. When Output Group 2 is turned on, 11 outputs could be turned
on. This allows Output Groups to be assigned within other Output Groups providing many
combinations.
Output groups 1 to 10 can be assigned by a user prole for applications such as elevator
control. See the XR150/XR350/XR550 User’s Guide (LT-1278) Output Group section for
additional information.
Output groups 11 to 20 cannot be assigned to a prole and are available for installation
applications such as special lighting, etc. To assign these groups to a prole, use Remote
Link™ or System Link™ software from DMP.
OUTPUT GROUPS
GROUP NO: -
GROUP NAME X X
OUTPUT NO 1: 0
OUTPUT NO 2: 0
OUTPUT NO 4: 0
OUTPUT NO 5: 0
OUTPUT NO 3: 0
OUTPUT NO 7: 0
OUTPUT NO 8: 0
OUTPUT NO 6: 0