XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
37
STATUS LIST
15.6 Supervisory Zones
Species the keypad addresses (1 through 16) where all su pervisory zone alarms and
troubles display. Supervisory zones are entered in the sta tus list and sound the keypad
buzzer until a valid user code is entered at any keypad address. If a trouble condition
remains in the display, the buzzer sounds at 10:00 am daily until the supervisory trouble is
cleared from the Status List.
15.7 Panic Zones
Species the keypad addresses (1 through 16) where all panic zone alarms and troubles
display. The name of the zone remains in the list until the zone re stores. The keypad
buzzer does not sound for panic alarms or troubles.
15.8 Emergency Zones
Species the keypad addresses (1 through 16) where all emer gency zone alarms and
troubles display. The name of the zone remains in the list until the zone re stores. The
keypad buzzer does not sound for emer gency alarms or troubles.
15.9 Auxiliary 1 Zones
Species the keypad addresses (1 through 16) where all Aux iliary 1 zone alarms and
troubles display. The name of the zone remains in the list until the zone restores. The
keypad buzzer does not sound for Auxiliary 1 alarms or troubles.
You can further dene which keypad address shows an Auxiliary 1 Zone event by entering
that area number in the Display Areas menu during Device Setup.
15.10 Auxiliary 2 Zones
Species the keypad addresses (1 through 16) where all Aux iliary 2 zone alarms and
troubles display. The name of the zone remains in the list until the zone restores. The
keypad buzzer does not sound for Auxiliary 2 alarms or troubles.
You can further dene which keypad address shows an Auxiliary 2 Zone event by entering
that area number in the Display Areas menu during Device Setup.
15.11 Communication Trouble
Species when communication troubles are displayed on keypads that are programmed to
display System Monitor Troubles. Default is NO.
Select YES to display communication trouble when any communication path fails.
Select ALL to display communication trouble only when all paths have failed.
SPRVISORY ZONES:
PANIC ZONES:
EMERGENCY ZONES:
AUX 1 ZONES:
AUX 2 ZONES:
COMM PATH TRBL:
NO YES ALL