Digital Monitoring Products XR150/XR350/XR550 Series Programming Guide
52
ZONE INFORMATION
18.23 Cross Zone
Select YES to enable cross zoning for this zone. Cross zoning requires one or more armed
zones to fault within a programmed time before an alarm report is sent to the receiver.
When the rst cross zoned zone trips, the cross zone time specied in System Options
begins to count down. When a second cross zoned zone trips or the rst zone trips a
second time before the end of the count down, the bell action assigned to the zone
activates and the panel sends an alarm report for both zones.
If no other cross zoned zone trips before the cross zone time expires, the panel sends
only a zone fault report to the receiver.
Cross zoning is not compatible with all zone types: You can not enable cross zoning for
Fire verify zones or for any Fire zones that have Retard Delay enabled.
18.24 Priority
Select YES to provide additional protection for the premises by requiring this zone to be
in a normal condition before its assigned area can be armed.
18.25 Fire Panel Slave Input
This option is available on Fire Zones (FI) only and allows a re zone the ability to
provide slave communication operation for a separate re alarm control panel. If YES,
this zone will transmit a restoral immediately when restored by the re panel being
monitored. A sensor reset is not required to generate the restoral message.
If NO, this zone will operate as a standard re type zone and a sensor reset is required
before the zone will return to normal. Default is NO.
18.26 Area Follower
Allows Night, Day, Aux 1, or Aux 2 burglary zones to be delayed by following any exit or
entry delay that is currently running in the area that is specied. Default is 0.
18.27 Zone Real-Time Status
Selecting YES allows Real-Time Status reports, such as Door Open or Closed with zone
number, to be sent using PC Log reporting. Selecting NO disables Real-Time Status for
this zone. Default is NO.
18.28 TrafcCount
This option is only displayed for NT and EX type zones. Select YES to provide reporting
to the receiver of the number of zone trips while in a disarmed state. The number
of trips will be included with the area closing message and reported to the central
station automation system. Trafc Count data for the 10 lowest numbered zones
with Trafc Count set to YES is also sent to the Virtual Keypad
TM
App if enabled at
vk.securecomwireless.com. Default is NO.
18.29 Zone Audit Days
Enter the number of days (0 to 365) allowed to elapse without the zone being tripped
before a fault message is sent. The message is sent to the receiver(s) programmed
to receive Supervisory/Trouble Reports at 10:00 am following the expiration of the
timer. Each time the zone is tripped, the Zone Audit Days timer restarts and begins
to countdown the number of days programmed. After the countdown expires, a fault
message is sent and the Zone Audit Days timer restarts and begins to countdown the
number of days programmed. Available for all zone types except re and re verify.
Enter 0 (zero) to disable this function. Default is 0 (zero).
18.30 Report with Account Number for Area
This option is only available for 24-hour zone types (Fire, Fire Verify, Panic, Emergency,
or Supervisory).
Enter the area number (1-32) to assign as a 24-hour zone type. This option
sends the
account number of the programmed area with messages. If the entered area number
does not exist or is not valid, the account number programmed in the Communication
section is sent. Select 0 (zero) to have the report sent with the account number
programmed in Communication. Default is 0.
CRS ZONE NO YES
PRIORITY NO YES
FIRE PANEL SLAVE
INPUT: NO YES
FOLLOW AREA: 0
ZONE REAL-TIME
STATUS NO YES
TRAFFIC COUNT
NO YES
ZONE AUDIT DAYS:
REPORT WITH ACCT
NO. FOR AREA: 0