Note: The panel makes ten attempts to reach the receiver. While attempting to contact the receiver, if the panel
needs to send an alarm report, the panel stops dialing and uses the phone line to send its report.
TEST: The panel allows you to perform a Communication Status Test on each component of the panel’s
cellular or network communication paths. While the Status List displays, enter 984 and press the COMMAND
key. The keypad display changes to NBR TEST PICKUP. Press the Select key under TEST to allow the panel to
perform a Communication Status Test. The display prompts the user for a user code to be entered. The user
code must have the authority to perform a System Test.
Upon entry of a Cell or Network path when prompted, the test runs and the results display on the keypad. See
Diagnostic Functions section for a description of the Communication Status results.
PICKUP: The panel picks up the phone line when Remote Link™ calls in. The phone must be ringing before
selecting PICKUP. After completing panel programming in Remote Link, connect to the panel by selecting
Panel > Connect. Refer to the Remote Link User’s Guide (LT-0565), or Help File for complete information about
connecting to panels.
While the panel displays in the status list and the telephone line at the panel rings, enter 984 and press the
COMMAND key. The keypad display changes to NBR TEST PICKUP. Press the Select key under PICKUP to allow
the panel to seize the line. The panel immediately seizes the phone line and sends a carrier tone to the
receiver. A verication process occurs and, if successful, the panel grants remote access to its programming
and Event Buffer.
After the panel has seized the line, send the le from Remote Link by selecting Panel > Send. Remote Link
then uploads the new programming into the panel. You may also Request Events by selecting Panel > Request
Events in Remote Link. The panel begins sending the rst event or access that occurred on or after the start
date specied by Remote Link and nishes by sending the last event or access that occurred on or before the
end date specied by Remote Link. If necessary, a Request Events upload in progress can be cancelled.
Keypad Displays
When the PICKUP option is used, the keypad displays LINE SEIZED. This indicates that the panel has seized the
line and is executing its program. If the line cannot be accessed, or if the PICKUP option is used before all
connect attempts are made, the keypad displays SYSTEM BUSY.
22.4 Using the Walk Test
The panel provides a walk test feature that allows a single technician to test the protection devices
connected to zones on the system. Conduct the Walk Test within 30 minutes of resetting the panel. The Walk
Test automatically ends if no zones are tripped for 20 minutes. TEST IN PROGRESS displays at all keypads
programmed with the same Display Areas features. When ve minutes remain, TEST END WARNING displays.
The Walk Test only tests zones assigned to the areas programmed into the keypad in Display Areas. If any
areas are armed the Walk Test does not start and SYSTEM ARMED displays.
Note: If the Panic Supervision option is enabled in SYSTEM OPTIONS, the panic button on any programmed key
fob can be tested during the Walk Test. When the panic button is pressed a verication message is sent by the
receiver.
Walk Test
To conduct the Walk Test, reset the control panel by momentarily placing a jumper on J16.
From the keypad, enter the code 8144.
The keypad displays WALK TEST for four seconds. If the system is monitored and the
communication type is DD or NET, the system sends a System Test Begin report to the
central station. After four seconds, the keypad displays the zone type choices for testing.
Zone Types
Select the zone type you want to test. An asterisk next to the zone type indicates the zone
type chosen for testing. Press the Select key again to deselect the zone type. When you
have selected all the zone types you want for testing, press the COMMAND key to display
the next Walk Test option. Pressing the Back Arrow key exits the Walk Test.
Note: For the Wireless Check-in Test, make sure no zone types are selected and press the
COMMAND key. Pressing the Back Arrow key exits the Walk Test.
BG (Burglary zones) - Select BG to test burglary zones. Includes all NT, DY, EX, A1, and A2
zones.
FI (Fire zones) - Select FI to test re zones. Includes all FI and FV zones.
PN (Panic zones) - Select PN to test panic zones. Includes all PN and EM zones.
SV (Supervisory zones) - Select SV to test supervisory zones. Includes all SV zones.
WALK TEST
BG FI PN SV